Graphite Ion Implant Shield Plate For Beam Line - Sputter Shield Plate

Send Inquiry
Graphite Ion Implant Shield Plate For Beam Line - Sputter Shield Plate
Details
Graphite Ion Implant Shield Plate For Beam Line %MAINIMG% A graphite shield plate lines the beam line of an ion implanter and catches the ions that miss the wafer, protecting the stainless steel chamber from sputtering and from the metal contamination that would otherwise reach the wafer....
Category
Graphite Parts
Share to
Description

Graphite Ion Implant Shield Plate For Beam Line

Graphite Ion Implant Shield Plate For Beam Line

A graphite shield plate lines the beam line of an ion implanter and catches the ions that miss the wafer, protecting the stainless steel chamber from sputtering and from the metal contamination that would otherwise reach the wafer. Graphite is used because it sputters into carbon, which is not a device-killing contaminant, and because it can be replaced cheaply.

Jincheng machines these shields as flat or curved plates with mounting holes and a defined aperture. The aperture edge is the critical feature: it must be clean, straight and correctly positioned, because a ragged aperture disturbs the beam and a mis-positioned one changes the dose uniformity across the wafer.

Key Features

  • Controlled aperture geometry - The beam aperture is machined with a straight edge and a deburred lip, so the beam profile is not disturbed and the edge does not sputter unevenly.

  • Carbon-only sputter - When the shield is hit, it releases carbon rather than iron, chromium or nickel, so the chamber stays free of metal contamination.

  • High-purity, low-outgassing grade - Selected graphite with low ash and low open porosity, so the shield does not outgas in the vacuum beam line.

  • Flat or curved profiles - Shields are machined flat or with a radius to match the chamber wall, with a consistent wall thickness.

  • Countersunk mounting holes - Holes are countersunk so screw heads sit below the surface and do not become sputter sources themselves.

  • Replaceable in situ - Plates are designed to be swapped through the chamber port, with handling features machined in.

Technical Specifications

Property Typical Value
Material High-purity isostatic graphite
Bulk density 1.85 to 1.92 g/cm3
Ash content Below 50 ppm
Open porosity Below 8 percent
Plate thickness 3 to 20 mm
Plate size Up to 400 x 300 mm
Aperture tolerance +/-0.1 mm
Edge squareness 0.05 mm
Flatness 0.1 mm across the plate
Mounting holes Countersunk M4 to M8
Surface finish Ra 1.6 um
Cleaning Ultrasonic clean and vacuum bake before packing

Applications & How to Use

Medium and high current implanters

Shields line the beam dump and the chamber wall so sputtered metal does not reach the wafer plane.

Beam dump liners

Thicker plates absorb the full beam current outside the wafer, and are replaced when the surface has eroded.

Aperture plates

The plate defines the beam cross section, so a clean aperture keeps dose uniformity within specification.

Chamber retrofit

Where an older tool shows metal contamination, graphite shields are added to convert the sputter products to carbon.

Sputter and deposition chambers

The same plate design is used as a sputter shield around targets to keep deposited film off the chamber wall.

Why Choose Jincheng

  • Aperture edges are machined straight and deburred, so the beam is not disturbed by a ragged opening.
  • Low-ash, low-porosity graphite is used so the shield does not outgas in the beam line vacuum.
  • Countersunk holes keep fasteners out of the sputter path.
  • Plates can be machined curved to match the chamber wall with a uniform thickness.
  • Parts are ultrasonically cleaned and vacuum baked before double bagging.
  • We hold drawings so a replacement shield matches the qualified geometry.

FAQ

Why is graphite used instead of stainless steel for beam line shields?

Because it sputters into carbon. A steel shield sputters iron, chromium and nickel, which are device contamination; carbon is comparatively benign.

How thick should a beam dump liner be?

Thickness depends on beam current and service interval; 10 to 20 mm is typical for a beam dump, 3 to 6 mm for wall shields.

Does the plate need a coating?

No. Bare high-purity graphite is standard; coatings can flake under ion bombardment and become a particle source.

How often are shields replaced?

Wall shields are typically replaced on a preventive maintenance interval, beam dump liners when surface erosion is visible.

Can you machine an aperture to a specific profile?

Yes, we machine straight, tapered and stepped apertures to the drawing and report the aperture dimension.

Related Graphite Products

Graphite Shadow Ring For Plasma Etch Chamber

Graphite Parts Machined To Drawing

Hot Tags: graphite ion implant shield plate for beam line - sputter shield plate, China graphite ion implant shield plate for beam line - sputter shield plate manufacturers, suppliers, factory, graphite electrodes for vacuum furnaces, graphite parts, high temperature vacuum graphite parts, vacuum furnace graphite bushings, vacuum furnace graphite crucibles, vacuum furnace graphite seals