Graphite Heat Sink Plate For IGBT Power Stacks

An IGBT stack fails at the interface, not in the die. The baseplate spreads heat into a sink, and if the sink and the baseplate expand at different rates the thermal interface degrades cycle by cycle until the junction temperature runs away.
Graphite has a thermal expansion close to that of the silicon package and a conductivity high enough to spread heat across the plate, so a graphite sink removes the mismatch that a copper sink introduces on wide temperature swings.
The plate is machined with a flat mounting face and a fin or pin field on the cooling side. Both faces are lapped, because a 0.05 mm flatness error over a 100 mm plate is enough to leave a dry patch under the module.
Key Features
-
Expansion matched to the package - thermal expansion close to the silicon package reduces interface shear
-
Through-plane conductivity - heat spreads laterally instead of forming a hot spot under the die
-
Lapped mounting face - flatness held so the interface material stays continuous
-
Pin or straight fin field - cooling geometry machined to the airflow or cold plate design
-
Electrically non-conductive - no isolation layer needed between the sink and a live baseplate
-
Custom outlines - plate size and hole pattern matched to the stack frame
Technical Specifications
| Property | Typical Value |
| Grade | high-density fine grain |
| Density | 1.88 - 1.95 g/cm3 |
| Thermal conductivity | 130 - 170 W/m.K in plane |
| Thermal expansion | 4.2 - 4.8 x 10-6 per K |
| Plate thickness | 4 - 20 mm |
| Flatness | 0.05 mm on the mounting face |
| Surface finish | Ra 0.8 on the mounting face |
| Pin diameter | 3 - 10 mm |
| Pin height | 5 - 30 mm |
| Plate size | up to 250 mm by 250 mm |
| Ash content | below 0.05 percent |
| Supply form | plate with or without pins |
Applications & How to Use
Traction inverter stacks
the plate spreads heat from paralleled IGBT modules
Industrial drive modules
a graphite sink avoids the copper-to-aluminium mismatch
Power cycling test rigs
matched expansion extends interface life under cycling
Rail and vehicle converters
the plate works with cold plate or forced air cooling
Replacement of aluminium sinks
graphite removes the bimetallic interface at the baseplate
Why Choose Jincheng
- Both faces are lapped and the flatness is reported, so interface contact is predictable
- Pin geometry is machined to the cooling design rather than to a stock pattern
- Grade is selected for through-plane conductivity, not just density
- Expansion values are supplied so the stack designer can check the mismatch
- Plates are machined in matched pairs for a stack, keeping the modules level
- Packing protects the lapped face with a removable film
FAQ
Is graphite strong enough for a clamp load
Compressive strength is high, but the plate must be loaded evenly, so a compliant interface pad is normally used
How does it compare with copper
Copper conducts better but expands far more, which is why graphite is chosen where cycling life matters
Can the pins be machined to our layout
Yes, pin diameter, height and pitch are all machined from the cooling design
Do you provide expansion data
Yes, expansion and conductivity values are reported with each batch
Related Graphite Products
Hot Tags: graphite heat sink plate for igbt power stacks, China graphite heat sink plate for igbt power stacks manufacturers, suppliers, factory, graphite block cylinder, graphite block for conductive heating, graphite block for fuel cell system, machined graphite block, solid block of graphite, solid graphite block