Graphite Clamp Bar For Electrode Column Joints

An electrode column is held together by joints that must carry current and mechanical load at the same time. A clamp bar that is too thin overheats at the joint, and one that is too stiff cannot follow the column as it expands.
The bar is machined as a graphite section with a matched contact radius, so it sits against the electrode surface over its full length rather than on two edges. Contact area is the design variable: it sets both the current density and the local temperature.
Bars are supplied in matched sets for a column, with the contact faces machined to the same radius so the current is shared evenly between clamps.
Key Features
-
Matched contact radius - the bar sits on the electrode surface along its full length
-
Even current sharing - sets are machined to the same radius for balanced load
-
Thermal expansion tolerance - the section follows the column as it grows
-
Bolted or clamped fixing - mounting pattern matched to the existing holder
-
High temperature strength - properties hold at the joint operating temperature
-
Custom lengths - bar length matched to the joint geometry
Technical Specifications
| Property | Typical Value |
| Grade | high-strength fine grain |
| Density | 1.85 - 1.92 g/cm3 |
| Resistivity | 8 - 14 microohm.m |
| Bending strength | 50 - 65 MPa |
| Bar length | 100 - 600 mm |
| Bar section | 20 mm by 20 mm to 80 mm by 80 mm |
| Contact radius | matched to electrode diameter |
| Radius tolerance | +/-0.10 mm |
| Service temperature | 1200 C in furnace atmosphere |
| Fixing holes | M10 to M24 |
| Ash content | below 0.05 percent |
| Supply form | matched set per column |
Applications & How to Use
Graphite electrode columns
clamp bars hold the joint and carry current
Resistance furnaces
the bar follows column expansion without loosening
Electrode holders
contact area is set for the current density
Column refurbishment
replacement bars restore contact without a new holder
High current DC lines
even current sharing between parallel clamps
Why Choose Jincheng
- Contact radii are machined to the electrode diameter and checked for each bar
- Bars for one column are machined as a set so current is shared
- Section size is chosen from the current density, not from stock
- Fixing patterns are copied from the existing holder
- Contact faces are inspected for flatness and radius
- Sets are packed with matching marks
FAQ
Why does contact radius matter
A radius mismatch loads two edges only, which raises local current density and overheats the joint
Can bars be re-machined
Yes, the contact face can be re-cut once if the radius is still adequate
How is current sharing checked
Bars in a set are measured for radius and contact length before shipment
Do you supply bolts
Graphite bolts and nuts can be included so the joint stays in one material
Related Graphite Products
Hot Tags: graphite clamp bar for electrode column joints, China graphite clamp bar for electrode column joints manufacturers, suppliers, factory, copper graphite electrodes, edm spark graphite electrode, graphite disc electrode, graphite edm electrodes, graphite electrodes electric arc furnace, graphite sheet electrode
