Graphite Quench Baffle For Controlled Gas Cooling

Send Inquiry
Graphite Quench Baffle For Controlled Gas Cooling
Details
Graphite Quench Baffle For Controlled Gas Cooling Gas quenching depends on how the cooling gas is distributed around the load. Without a baffle, the gas enters the chamber as a jet that cools one face faster than the rest, and the resulting distortion shows up as cracking or excessive movement....
Category
Graphite Hot Zone Components
Share to
Description

Graphite Quench Baffle For Controlled Gas Cooling

Graphite Quench Baffle For Controlled Gas Cooling

Gas quenching depends on how the cooling gas is distributed around the load. Without a baffle, the gas enters the chamber as a jet that cools one face faster than the rest, and the resulting distortion shows up as cracking or excessive movement.

The baffle is a perforated graphite plate placed between the gas inlet and the load. Hole pattern and open area are set from the gas flow rate, so the jet is broken into a diffuse flow before it reaches the parts.

Key Features

  • Perforated diffusion plate - the inlet jet is broken into a diffuse flow across the load

  • Open area matched to flow - hole count and diameter are set from the gas rate

  • Directional vanes - flow can be biased to the faces that need more cooling

  • Thermal shock tolerance - the baffle survives the rapid cooling part of the cycle

  • Replaceable - the baffle is a wear part, replaced without touching the nozzle

  • Custom outlines - plate shape matched to the chamber section

Technical Specifications

Property Typical Value
Grade fine-grain, high strength
Density 1.85 - 1.92 g/cm3
Thickness 6 - 20 mm
Open area 25 - 60 percent
Hole diameter 4 - 20 mm
Plate size up to 700 mm by 700 mm
Flatness 0.20 mm
Bending strength 45 - 62 MPa
Service temperature 1200 C in vacuum
Vane angle 0 - 30 degrees where fitted
Mounting slotted for expansion
Supply form single plate or plate with vane set

Applications & How to Use

High pressure gas quenching

the baffle spreads the inlet jet across the load

Vacuum oil quenching

a baffle limits direct impingement on one face

Aluminium solution treatment

even gas flow reduces distortion across thin sections

Tool hardening

the vane set can bias flow to heavy sections

Retrofit of existing quench ports

the outline is copied from the chamber section

Why Choose Jincheng

  • Open area is calculated from the gas flow, not chosen by eye
  • Holes are drilled in a fixed pattern so the flow stays reproducible between baffles
  • Plates are machined flat and slotted for expansion before the final check
  • Vanes can be added where one face needs more cooling
  • Baffles are consumables and are priced to be replaced
  • Outlines are cut from the chamber drawing for a drop-in fit

FAQ

How much open area is right

It depends on the gas flow and chamber volume; 25 to 60 percent is the usual working range we machine

Can the baffle reduce cooling speed

Yes, that is the trade-off: it trades some cooling rate for uniformity

Does it need replacing often

It is a wear part, but life is long unless the gas stream carries particles

Can vanes be added later

Vanes must be designed with the plate, because they change the flow pattern and mounting

Related Graphite Products

Graphite Vacuum Hardening Rack

Graphite Heat Shield Baffle Disc

Graphite Grade Selection Checklist