Graphite Filter Mesh For Molten Salt Loops

Molten salt loops carry oxide particles that erode pumps and block narrow channels, and a metal screen corrodes in the salt. A perforated graphite plate placed in the loop removes the particles without adding a corrosion source.
The plate is machined with a hole pattern sized to the smallest passage downstream, and the open area is set so the pressure drop stays inside the pump margin. Plates are usually stacked in a housing so the finest screen sits last.
Because graphite is brittle, the plate is supported around its rim and, where the housing allows, a coarse backing plate is supplied to take the structural load.
Key Features
-
Corrosion resistant in salt - graphite does not react with chloride or fluoride melts
-
Hole pattern set to the downstream gap - particles larger than the narrowest passage are stopped
-
Open area controlled - pressure drop stays within the pump margin
-
Stackable screens - coarse and fine plates are used in one housing
-
Backing plate option - a coarse plate carries the structural load
-
High temperature capability - usable well above the salt loop temperature
Technical Specifications
| Property | Typical Value |
| Grade | high-density fine grain |
| Density | 1.88 - 1.95 g/cm3 |
| Ash content | below 0.05 percent |
| Plate thickness | 3 - 12 mm |
| Hole diameter | 0.5 - 8 mm |
| Hole pitch | 1.5 - 15 mm |
| Open area | 15 - 55 percent |
| Plate diameter | 50 - 400 mm |
| Flatness | 0.15 mm |
| Service temperature | 800 C in molten salt |
| Support | rim support or backing plate |
| Supply form | single plate or stacked set |
Applications & How to Use
Molten salt test loops
screens remove oxide particles before they reach the pump
Thermal storage circuits
the filter protects narrow channels from blockages
Salt purification rigs
stacked plates grade the particle size
High temperature chemical lines
graphite is unaffected by the process fluid
Retrofit of metal screens
the plate drops into an existing housing
Why Choose Jincheng
- Hole patterns are drilled from the downstream gap, so the filter actually protects the narrowest passage
- Open area is calculated against the pump margin rather than maximised
- Rim support is designed into the plate so it does not rely on the housing alone
- Coarse backing plates are supplied where the differential pressure is high
- High-density grade resists erosion by entrained particles
- Plates are flatness checked before packing
FAQ
Can the plate be cleaned and reused
Yes, it can be removed, cleaned and reinstalled, but the hole pattern should be inspected for erosion
How fine a particle can it stop
Holes down to 0.5 mm are machinable, which covers most loop protection needs
Why graphite instead of stainless mesh
Stainless corrodes in chloride and fluoride salts, and the corrosion products add to the particle load
Is differential pressure a problem
It is the main design constraint, so open area is set against the available pump margin
Related Graphite Products
Hot Tags: graphite filter mesh for molten salt loops, China graphite filter mesh for molten salt loops manufacturers, suppliers, factory, carbon graphite parts for vacuum furnaces, high temperature vacuum graphite parts, vacuum furnace graphite bushings, vacuum furnace graphite crucibles, vacuum furnace graphite parts, vacuum furnace graphite screws