EDM Parameters For Graphite: Setting The Machine For The Grade

Graphite electrodes behave differently from copper, and settings copied from a copper program usually produce either excessive wear or a poor surface. The main differences are higher allowed current, a different wear pattern and a greater sensitivity to flushing.
The practical approach is to set the machine by operation: roughing can be aggressive with high current and short off-time, while finishing needs lower current and longer off-time to control wear and surface.
This page sets out the relationships rather than a parameter table, because the right numbers depend on the machine and the grade.
Current and wear
Higher current raises removal rate and, up to a point, reduces relative wear. Beyond that point the electrode corner wear accelerates and the shape that matters is lost, which shows up as a cavity dimension that drifts during the run.
On-time and off-time
Long on-time with short off-time leaves debris in the gap and produces arcs that damage both electrode and workpiece. Increasing off-time to clear the gap costs cycle time and protects the electrode, and on deep ribs it is the parameter that decides whether the job finishes.
Flushing
Graphite produces more debris volume per unit of removal than copper, so flushing has to be stronger. Through-spindle flushing, jet flushing and a defined jump height are process decisions, not setup details, because debris that stays in the gap changes the erosion.
Roughing versus finishing
Roughing is about removal and can tolerate wear, so high current and short off-time are appropriate. Finishing is about shape and surface, so lower current, longer off-time and a smaller jump produce the result, at a slower rate.
Recording settings by job
Settings that worked should be recorded against the job, the grade and the electrode geometry, because the same numbers rarely transfer between cavity shapes. A simple log becomes the shop's own parameter library.
Practical Checklist
- Do not copy copper settings onto graphite.
- Increase off-time to clear debris on deep ribs.
- Flushing strength matters more on graphite.
- Record settings per job and per electrode geometry.
