Graphite Powder Sieving: How To Specify A Cut That Holds

A Mesh Number Is Not A Distribution
Buying powder to a mesh number specifies an upper bound, not a particle size distribution. A minus 325 mesh powder can contain a wide spread of fines, and that spread is what changes pressing behaviour, conductivity and surface finish.
A useful specification therefore states the cut, the typical distribution and an upper limit on the coarse tail, because a small fraction of oversize particles causes more defects than the same fraction of fines.
Values Worth Putting In The Spec
State the sieve cut, the D50 and a D90 or D99 figure from a laser measurement, and the tap density or apparent density relevant to your forming process. If the powder is used for pressing, add the ash content and moisture limit.
Sampling method matters too: a specification that does not say how the sample is taken invites disputes, because fines segregate toward the bottom of a container.
Checking Incoming Lots
Check the coarse tail first, since oversize particles show up as pits and inclusions in the finished part. A quick sieving test on receipt is cheaper than finding the problem after pressing.
Keep the sieve and measurement method in the record so that two suppliers can be compared on the same basis, and re-check whenever a supplier changes their milling process.
Conclusion
Specify distribution, not a mesh number. Add the coarse tail limit, density figures and sampling method, and test on receipt. Graphite powder grades are available with sieving and ash data per lot.
Machined graphite parts and material grades are listed on the product index; for grade comparison see the selection checklist.